Batumi Bypass Tunnel N 4 Automation

Awesome Image
Awesome Image

Batumi Bypass Tunnel N 4 Automation

  • Design and Construction

 

  • N1 HVAC
    1. CFD analysis
    2. Mechanical tunnel ventilation and
  • smoke extraction system according to CFD analysis
    3. CO/NO gas sensors
    4. Air direction and velocity sensors
    5. Full HVAC of technical roomN2 Firefighting
    1. Pumping station
    2. Fire cabinets with hoses and fire extinguishers
    3. FM-200 system for electrical rooms
    4. Sprinter system for control roomN3 Weak Currents
    1. Fire alarm
    2. Public address and voice evacuating system
    3. CCTV
  • Traffic information board
    5. Safety signs
    6. Barriers and traffic lightsN4 Tunnel Lighting
    1. Roadway lighting
    2. Evacuating lighting
    3. Barriers marking lightsN5 Tunnel Automation
  • Operating Control Center Building
  • SCADA Server
  • Operator Workstation
  • Operator Consoles
  • UPS
  • Network Cabinet

    N6 Electrical Power Supply
    1. Electrical power supply of the technical part
    2. Lighting electrical power supply
  • Uninterruptible power supply (UPS)
    4. Backup power supply – diesel generator
    5. Transformer substation